Abstract:In order to effectively control the voltage sag of natural gas compressor stations with high-power motor-driven centrifugal compressor units, a hierarchical mitigation scheme for voltage sag in compressor stations is proposed based on the operation information of two typical compressor stations with high-power motor-driven centrifugal compressor units (hereinafter abbreviated as compressor stations) and by analyzing the characteristic level of voltage sag and the failure probability of sensitive equipment in compressor stations. Firstly, according to the equipment parameter information of compressor stations, the type, distribution and connection relationship of sensitive equipment for voltage sag in compressor stations are analyzed, and then the mechanism of voltage sag tolerance of sensitive equipment in the station is analyzed. Combined with the historical data, the characteristic level of voltage sag in compressor stations is fitted by nuclear density estimation method, and the failure probability of voltage sag of sensitive equipment is evaluated by energy loss function. Finally, according to the characteristic level of voltage sag and the failure probability of sensitive equipment in compressor stations, an effective hierarchical mitigation scheme for voltage sag is proposed.