藏区孤网 QV 特性与过电压风险防控
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TM71

基金项目:


Q - V Characteristic and Overvoltage Prevention for Isolated Power Grid in Tibetan Area of Sichuan Province
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
    摘要:

    工频过电压问题是威胁四川藏区偏远山区孤网运行时的主要问题。首先提出了适用于偏远山区电网孤网运 行的 N - 1 校核标准。在此基础上,以四川藏区典型结构的电网为例,从稳态 QV 特性以及考虑发电机低励限制的机 电暂态特性的角度,分析了偏远山区电网孤网运行时的过电压产生机理。最后,提出了降低偏远山区电网孤网运行 过电压风险的运行措施。所做研究对于提升偏远山区电网运行的安全稳定性具有指导性意义。

    Abstract:

    wer - frequency overvoltage is a major threat to the isolated power grid of remote mountainous areas in Tibetan area of Sichuan province. Firstly,a novel N - 1 check principle for isolated power grid in remote mountainous areas is proposed. Furthermore,the mechanism of power - frequency overvoltage in isolated power grid is analyzed based on steady - state Q - V model and electromechanical transient model with consideration of low excitation limit. Finally,the countermeasures to reduce the damage of power - frequency overvoltage are presented. This research is helpful for promoting the security level of the isolated power grid in remote mountainous areas.